controls@h1build release 0$ make h1isiham4 command is make h1isiham4 Cleaning h1isiham4... Done Parsing the model h1isiham4... Done Building EPICS sequencers... Done Building front-end Linux kernel module h1isiham4... Done RCG source code directory: /opt/rtcds/rtscore/advLigoRTS-2.8.2 The following files were used for this build: /opt/rtcds/userapps/release/cds/common/models/ODCV2.mdl /opt/rtcds/userapps/release/cds/common/models/ODC_CHAN.mdl /opt/rtcds/userapps/release/cds/common/src/BLRMSFILTER.c /opt/rtcds/userapps/release/cds/common/src/ODC_ADD_PARITY_INT.c /opt/rtcds/userapps/release/cds/common/src/ODC_LATCH.c /opt/rtcds/userapps/release/hpi/common/models/hepitemplate.mdl /opt/rtcds/userapps/release/isc/common/models/ISC_common.mdl /opt/rtcds/userapps/release/isi/common/models/Offset_DOF.mdl /opt/rtcds/userapps/release/isi/common/models/WD_Checker.mdl /opt/rtcds/userapps/release/isi/common/models/isi2stagemaster.mdl /opt/rtcds/userapps/release/isi/common/models/isihammaster.mdl /opt/rtcds/userapps/release/isi/common/src/BLENDDIFF.c /opt/rtcds/userapps/release/isi/common/src/BLENDMASTER.c /opt/rtcds/userapps/release/isi/common/src/ISIRESET.c /opt/rtcds/userapps/release/isi/common/src/ISIWD_GPS.c /opt/rtcds/userapps/release/isi/common/src/RAMP_BIAS.c /opt/rtcds/userapps/release/isi/common/src/WD_CHECKER.c /opt/rtcds/userapps/release/isi/h1/models/h1isiham4.mdl Successfully compiled ********************* make succeeded log file is /opt/rtcds/lho/h1/data/buildlog/h1isiham4_2014_04_16_12:04:23 controls@h1build release 0$ controls@h1build release 0$ controls@h1build release 0$ make install-h1isiham4 command is make install-h1isiham4 Installing system=h1isiham4 site=lho ifo=H1,h1 Installing /opt/rtcds/lho/h1/chans/H1ISIHAM4.txt Installing /opt/rtcds/lho/h1/target/h1isiham4/h1isiham4epics Installing /opt/rtcds/lho/h1/target/h1isiham4 Installing start and stop scripts /opt/rtcds/lho/h1/scripts/killh1isiham4 Performing install-daq Updating testpoint.par config file /opt/rtcds/lho/h1/target/gds/param/testpoint.par /opt/rtcds/rtscore/advLigoRTS-2.8.2/src/epics/util/updateTestpointPar.pl -par_file=/opt/rtcds/lho/h1/target/gds/param/archive/testpoint_140116_120453.par -gds_node=61 -site_letter=H -system=h1isiham4 -host=h1seih45 Installing GDS node 61 configuration file /opt/rtcds/lho/h1/target/gds/param/tpchn_h1isiham4.par Installing auto-generated DAQ configuration file /opt/rtcds/lho/h1/chans/daq/H1ISIHAM4.ini Installing Epics MEDM screens Running post-build script make succeeded log file is /opt/rtcds/lho/h1/data/buildlog/install-h1isiham4_2014_04_16_12:04:53