controls@h1build release 0$ make h1isiham5 command is make h1isiham5 Cleaning h1isiham5... Done Parsing the model h1isiham5... Done Building EPICS sequencers... Done Building front-end Linux kernel module h1isiham5... Done RCG source code directory: /opt/rtcds/rtscore/advLigoRTS-2.8.2 The following files were used for this build: /opt/rtcds/userapps/release/cds/common/models/ODCV2.mdl /opt/rtcds/userapps/release/cds/common/models/ODC_CHAN.mdl /opt/rtcds/userapps/release/cds/common/src/BLRMSFILTER.c /opt/rtcds/userapps/release/cds/common/src/ODC_ADD_PARITY_INT.c /opt/rtcds/userapps/release/cds/common/src/ODC_LATCH.c /opt/rtcds/userapps/release/hpi/common/models/hepitemplate.mdl /opt/rtcds/userapps/release/isc/common/models/ISC_common.mdl /opt/rtcds/userapps/release/isi/common/models/Offset_DOF.mdl /opt/rtcds/userapps/release/isi/common/models/WD_Checker.mdl /opt/rtcds/userapps/release/isi/common/models/isi2stagemaster.mdl /opt/rtcds/userapps/release/isi/common/models/isihammaster.mdl /opt/rtcds/userapps/release/isi/common/src/BLENDDIFF.c /opt/rtcds/userapps/release/isi/common/src/BLENDMASTER.c /opt/rtcds/userapps/release/isi/common/src/ISIRESET.c /opt/rtcds/userapps/release/isi/common/src/ISIWD_GPS.c /opt/rtcds/userapps/release/isi/common/src/RAMP_BIAS.c /opt/rtcds/userapps/release/isi/common/src/WD_CHECKER.c /opt/rtcds/userapps/release/isi/h1/models/h1isiham5.mdl Successfully compiled ********************* make succeeded log file is /opt/rtcds/lho/h1/data/buildlog/h1isiham5_2014_58_16_13:58:07 controls@h1build release 0$ make install-h1isiham5 command is make install-h1isiham5 Installing system=h1isiham5 site=lho ifo=H1,h1 Installing /opt/rtcds/lho/h1/chans/H1ISIHAM5.txt Installing /opt/rtcds/lho/h1/target/h1isiham5/h1isiham5epics Installing /opt/rtcds/lho/h1/target/h1isiham5 Installing start and stop scripts /opt/rtcds/lho/h1/scripts/killh1isiham5 Performing install-daq Updating testpoint.par config file /opt/rtcds/lho/h1/target/gds/param/testpoint.par /opt/rtcds/rtscore/advLigoRTS-2.8.2/src/epics/util/updateTestpointPar.pl -par_file=/opt/rtcds/lho/h1/target/gds/param/archive/testpoint_140116_135834.par -gds_node=62 -site_letter=H -system=h1isiham5 -host=h1seih45 Installing GDS node 62 configuration file /opt/rtcds/lho/h1/target/gds/param/tpchn_h1isiham5.par Installing auto-generated DAQ configuration file /opt/rtcds/lho/h1/chans/daq/H1ISIHAM5.ini Installing Epics MEDM screens Running post-build script make succeeded log file is /opt/rtcds/lho/h1/data/buildlog/install-h1isiham5_2014_58_16_13:58:34 controls@h1build release 0$ controls@h1seih45 /opt/rtcds/lho/h1/release 0$ starth1isiham5 Specified filename iocH1.log does not exist. h1isiham5epics H1 IOC Server started Burt restored /opt/rtcds/lho/h1/target/h1isiham5/h1isiham5epics/burt/safe.snap Old : H1:FEC-62_BURT_RESTORE 1 New : H1:FEC-62_BURT_RESTORE 1 * Starting h1isiham5 awgtpman ... [ !! ] controls@h1seih45 /opt/rtcds/lho/h1/release 0$