Latest TF/Spectras Test Results for HSTS I1-SRM
These are the latest TF/Spectras Test Results for HSTS I1-SRM


Non-image files attached to this report
Comments related to this report
stuart.aston@LIGO.ORG - 21:49, Wednesday 12 June 2013 (6729)
Both undamped and damped transfer functions for the India SRM (HSTS) raise no concerns. All peaks are in agreement with model predictions and are consistent with other HSTS suspensions. Also, power spectra agree with noise floor expectations, with the exceptions of M3 L and P DOFs (pg 25 & 26). These are however consistent with other HSTS measurements (so I shall investigate if the correct sensor noise expectation is being used).

Please consider the I1-SRM suspension approved for India. Nice work again the LHO triple assembly team! 