hugo.paris@LIGO.ORG - posted 11:01, Friday 14 February 2014 (10101)
HAM4-ISI - Added SUS SR2 WD connection

h1isiham4.mdl was updated to receive SUS WD signals from h1sussr2.

HAM4-ISI's model was recomiled and restarted successfully (See attached Log.txt). The new version of h1isiham4.mdl was commited to the SVN:
/opt/rtcds/userapps/release/isi/h1/models/h1isiham4.mdl -r7133

The DAQ had was restarted at 11:01AM.

The Safe.snap of HAM4-ISI was updated with the latest matrices and filers to be engaged and commited to the SVN:
/opt/rtcds/userapps/release/isi/h1/burtfiles/h1isiham4_safe.snap    -r7132

h1sussr2.mdl still needs to be updated, as it current sends out a constant (coding SUS untripped) to the ISI model. See attached screenshot.

Work was performed under WP #4445 which is now closed.