Arm locking tonight

Sheila, Alexa

After spending the afternoon on the arm locking, we spent some time looking at the COMM handoff.  (Plots coming in the morning...)

 

I am leaving the arm cavity locking, PRM parked and ITMY misalinged, and the alingment servos off. 

Comments related to this report
alexan.staley@LIGO.ORG - 11:37, Friday 21 February 2014 (10243)

Here are some of the plots Sheila was referring to..

With the COMM PLL Gain at 19dB, we adjusted the CM Board Input 1 gain and looked at the amplitude spectrum from output 2 (i.e. the common path with the handoff engaged). We have data for a gain of 9dB, 12dB, 15dB, 18dB, and 21dB. These are plotted in Comm_Path_NoiseSpec.pdf.

I have also attached a GIF of the common path TF with the UGF at 3.9kHz, and 16kHz as we increased the gain.

Images attached to this comment
Non-image files attached to this comment
sheila.dwyer@LIGO.ORG - 11:55, Friday 21 February 2014 (10245)

In the first GIF that Alexa posted the reference trace is PLL gain 31, CM board IN1 gain 15.  In the active trace the PLL gain has been turned down.  

These plots show that we could push the bandwidth up to 35 kHz if we wanted to.