Reports until 08:11, Tuesday 29 July 2014
H1 SUS
stuart.aston@LIGO.ORG - posted 08:11, Tuesday 29 July 2014 (13036)
HAM3 - PR2 & MC2 (HSTS) M1-M1 Phase 3a TFs are clear (again)
[Stuart A, Arnaud P]

After the door was briefly removed from HAM3 to recover first contact from a witness optic (see LHO aLOG entry 12994) we repeated TFs again on PR2 & MC2 (HSTS) suspensions to verify that no issues had since developed, as follows:-

- PR2 M1-M1 undamped (2014-07-28_1090637500_H1SUSPR2_M1_damp_OFF_ALL_TFs.pdf) 
- MC2 M1-M1 undamped (2014-07-28_1090619695_H1SUSMC2_M1_damp_OFF_ALL_TFs.pdf)

HAM3 ISI Status: ISI damped, no isolation loops running.

PR2 & MC2 alignment: No offset was applied during this measurement.

The undamped measurements from above have been compared with each other as well as the model (allhstss_2014-07-29_Phase3a_H1HSTSs_M1_Doff_ALL_ZOOMED_TFs.pdf).

Summary: 

Both PR2 & MC2 M1-M1 TFs show good agreement with the model and perform consistently, thus raising no concerns.

All data, scripts and plots have been committed to the sus svn as of this entry.
Non-image files attached to this report