Reports until 12:23, Wednesday 27 August 2014
H1 AOS (PEM)
sudarshan.karki@LIGO.ORG - posted 12:23, Wednesday 27 August 2014 - last comment - 14:44, Friday 29 August 2014(13623)
AGM Tiltmeter Installation
S. Karki

The zeroing of Applied Geomechanics Tiltmeter is completed at ENDX and should be up and running. It was so off-scale, using a bubble-level and voltmeter did the trick to bring it down to reasonable level and after that I used the DTT to level it more. 
Images attached to this report
Comments related to this report
sudarshan.karki@LIGO.ORG - 11:23, Friday 29 August 2014 (13670)
Jeff, Krishna, Robert

here is the calibrated (against seismometer) amplitude spectral density.
Non-image files attached to this comment
robert.schofield@LIGO.ORG - 14:44, Friday 29 August 2014 (13679)

That doesnt look quite right. Lets debug via email. -Robert