evan.hall@LIGO.ORG - posted 17:49, Wednesday 22 October 2014 (14588)
BS oplev: gain+whitening adjustments

Jeff, Rana, Alexa, Kiwamu, Evan

Rana noticed that the BS oplev spectra (pitch and yaw) were suspiciously flat, perhaps indicating that they were dominated by ADC noise.

To fix this, Rana and I attached a DIP-switch jumper board (D1001631v2) to the 37-pin dsub on the BS oplev whitening board. This allows us to set bits that control the gain and whitening.

For each of the four segments, we flipped bits 2 and 4 (which increases the gain) and bit 5 (which engages a single whitening stage) to high; all others are low. Then we engaged the antiwhitening filters for each segment.

The first attachment shows the BS oplev spectra before (green, brown) and after (cyan, magenta) the gain+whitening+antiwhitening, with the loop off. We now appear to be resolving more features in the spectra.

The second attachment shows the BS oplev spectra after gain+whitening+antiwhitening, with the loop off (cyan, magenta) and on (red, blue).