Displaying report 1-1 of 1.
Reports until 01:40, Thursday 06 November 2014
H1 ISC
alexan.staley@LIGO.ORG - posted 01:40, Thursday 06 November 2014 - last comment - 16:52, Thursday 06 November 2014(14882)
ETMY L1, L3 crossover

Nic, Alexa, Sheila, Evan, Dan

 

We wanted to measure the crossover between L1 and L3 of ETMY. We took a transfer function from LOCK_L1/L3 to ALS-Y_REFL_SERVO_CTRL_OUT with green locked to the yarm. We found an old template made by Sheila and Stefan for the L1 stage. We repeated the measurement for a few data points (green trace), and it seemed the same as the old measurement (blue) so we aborted the measurement and went with the assumption that it was still a valid measurement. We then measured for the L3 stage (red trace). Clearly the crossover between L1 and L3 is about 2 Hz as expected.  Nic plans on dividing these two transfer functions tomorrow morning... 

Fo reference the xml file is located here: /ligo/home/sheila.dwyer/ALS/HIFOXY/Y_UIM_2.xml

Images attached to this report
Comments related to this report
nicolas.smith@LIGO.ORG - 16:52, Thursday 06 November 2014 (14897)SUS

Here is the ratio of the ETMY UIM and ESD actuator gains (red and blue traces in original post).

It looks like our crossover is about 2Hz and the phase margin is about 45 degrees.