alexan.staley@LIGO.ORG - posted 15:59, Thursday 15 January 2015 - last comment - 18:38, Thursday 15 January 2015(16097)
ALS DIFF OK

Sheila, Kiwamu, Evan, Nergis, Alexa

We have been able to lock ALS DIFF for +20 min.

I have attached screen shots of the ALS DIFF filter configuration. In addition, I have attached the ALS_DIFF Spectrum, UIM/ESD crossover, and OLTF. The ALS DIFF spectra shows that the noise is suffeciently low to move onto locking.

Images attached to this report
Non-image files attached to this report
Comments related to this report
alexan.staley@LIGO.ORG - 18:38, Thursday 15 January 2015 (16104)

We have gone back to FM1, FM2 ON, FM10 OFF, Gain -1 for the ETMX L1 L2P. We also turned off FM3 of the top mass L and Y dampling filters.