ETMX oplev recentered

Nergis, Evan

The ETMX oplev was badly miscentered in yaw. We have recentered it.

We did not make any changes to the whitening board settings. A picture is attached.

Images attached to this report
Comments related to this report
evan.hall@LIGO.ORG - 16:23, Friday 16 January 2015 (16121)

Sheila, Evan

We have now engaged the ETMX L2 pitch oplev damping with the following filter settings:

  • FM1: zpk([0],[50],10,"n")
  • FM7: ellip("LowPass",4,2,40,15)
  • Gain = -0.5 ct/ct

An OLTF of the damping loop is attached.

Qualitatively, this loop appears to make the buildup of ALS-X light more stable during locking activities.