Displaying report 1-1 of 1.
Reports until 16:22, Monday 19 January 2015
H1 ISC (ISC, SUS)
evan.hall@LIGO.ORG - posted 16:22, Monday 19 January 2015 (16143)
ETMX bounce mode damping

Sheila, Alexa, Evan

For a few hours today, ALS DIFF locking was blocked by the appearance of the 9.8 Hz ETMX bounce mode. We used the procedure in LHO#15247 to damp it. We let it damp for about an hour, and then proceeded with locking activity.

In the attached plot, blue and red are before and after damping, respectively.