DRMI3f+arms with CARM controlled by sqrt(TRX+TRY)

Sheila, Alexa, Elli, Rana, Evan

Summary

Building on this afternoon's work of transitioning control of the X arm from ALS COMM to sqrt(TRX) [LHO#16250], we have been able to recover the handoff of CARM from ALS COMM to sqrt(TRX+TRY).

Next steps are to try to reduce the CARM offset further, transition to RF DARM, transition to the in-vacuum transmon QPDs for CARM, transition to digital REFL9I for CARM, and then reduce the CARM offset all the way to 0 pm.

Details

The transition sequence is largely the same as for the X arm case. I repeat the sequence here, with modifications as appropriate:

Sheila has put these steps into the Guardian, but they haven't been extensively tested yet.

The attached plots and data give the OLTF of CARM controlled by sqrt(TRX+TRY).

Images attached to this report
Non-image files attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 01:00, Sunday 25 January 2015 (16253)

Some lock loss times when we were on TR CARM.  

7:26:10 Jan 25 UTC

8:11:20

8:13

5:54:35

rana.adhikari@LIGO.ORG - 16:16, Sunday 25 January 2015 (16256)ISC

A crucial  point is that we were never able to actually shut off the ALS. Although we reduced the ALS gain by 30-40 dB after bringing on the Thorlabs/Transmon signal, actually switching off the ALS signal using the IN2 on/off switch on the CM board broke the lock each time. Also turning the gain down further using the gain slider on the summing board (before the CM board) also broke the lock.

At the time of the lock losses, the CARM UGF was ~100-150 Hz, so it seems like the ALS would have no effect on the loop. Since we're able to hear the gain slider steps on the CARM audio (because of our great new speakers), we suspect that the ~mV level offsets in the gain slider and the on/off switches are the problem.

Talking with Daniel today, we think one strategy is to increase the level of the TR_CARM signal (either digitallly or analogly) before it gets to the CM board so that mV offsets don't matter as much. We can compensate this gain increase by reducing the Additive Offset gain slider in the IMC board from its current value of +16 dB, to something more like -20 dB. We know from log #16251 that the required AO range is going to be less than 100 Hz.