Unit 2, Isolation loop
We are working on the implementation of the isolation loops. What we did to start:

- we use the normalization filters from HAM6. The first page shows the normalized displacement and GS13. The GS13 will have to be tweaked a little bit.
- we use the 1Hz blend filters from HAM6.
- the un-damped super-sensor using these raw filters is shown on page 3.

What's next:
- we tweak the GS13 normalization
- we are going to take damped data over the week end
- we built the damped super-sensor
- we design and implement the isolation filter