suresh.doravari@LIGO.ORG - posted 18:11, Saturday 28 March 2015 (17564)
Measurement of misalignment in IMC input beam which causes jitter to RIN coupling

An attempt to measure the amount of misalignment that is currently present  in the PSL-to-IMC coupling.

First I centered the direct reflection from the IMC onto the WFS A and WFS B sensors.  There was about 30% reduction in the RIN.  See attached png and xml files: IMC_jitter_centering.*

 

Next, I  injected an excitation in to the PSL_PZT pitch and yaw  at 7.33 Hz .  I then took a PSD of the IM4_TRANS_SUM signal to measure the power fluctuations in at 7.33 Hz and 14.66 Hz (P1f and P2f) respectively. 

Attached files show these peaks in the IM4_TRANS_SUM spectra.  Attached also are the xml files which have the data and an excel file which has the computation of the amount of misalignment.

In summary: 

       1)  Pitch misalignment is 0.6% of the IMC cavity beam divergence

       2) Yaw misaligment is 1.2% of the IMC cavity beam divergence.

An attempt to see how the misalignment could have arisen:

I  tried to vary several offsets to see whether this coupling from jitter to RIN could be changed.  The ones I tried are

a) Common mode offset in the MC servo board: To see if a length offset is causing this H1:IMC-REFL_SERVO_COMOFS

b) Slow offset in the MC servo board H1:IMC-REFL_SERVO_SLOWOFS

c) Slow out offset in the MC servo board H1:IMC-REFL_SERVO_SLOWOUTOFS

d) DOF1 to DOF3 offsets in both both pitch and yaw in the MC WFS servo loops.

None of these by themselves had a significant impact on the jitter to RIN coupling.  More investigation required.

 

And now for those nay sayers :-)  Things I did not do!! 

1)  I returned all offsets to where they were.

2) The MC2 spot is centered and the IM4_TRANS spot has not moved from before to after my WFS centering => output beam has not shifted

3) The WFS outputs were not off loaded: the IMC alignment slider values have remained the same

4) No other Pico motors other than that of IMC WFS A and IMC WFS B were touched.

So in essence if something broke, its not coz of me!!  :-p