J. Kissel Using the DARM OLGTF model that we've updated the CAL-CS and GDS low-latency calibrations, I've generated an inverse actuation function for the hardware injections. This is an update to the filter designed for the LHO mini-run (see LHO aLOG 18115). The updated filter has been loaded into FM2 of the H1:CAL-INJ_HARDWARE filter bank, as well as the H1:CAL-INJ_BLIND filter bank, BUT NOT YET TURNED ON. It will be turned on tomorrow during maintenance. Recall that this filter should be assigned the same uncertainty as is true for the DARM Open Loop Gain transfer function (see LHO aLOG 18769) -- 50% and 20 [deg], mostly because of the frequency dependent discrepancy between the model vs measured DARM open loop gain transfer function. Indeed we are now quite certain that the model vs. measurement discrepancies / features seen at ~500, ~1000, ~1500 [Hz] are inaccurately modeled violin modes of the ETMY QUAD. Further, we're confident that we can *remove* these features from future actuation functions by retuning the ETMY UIM / PUM / TST control authority, which we will do immediately following ER7. Er, well, immediately following the vent that immediately follows ER7. So we expect future DARM OLGTFs and therefore inverse actuation function uncertainty to be much less. Details ----------- I've used the following DARM OLGTF model, /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/PreER7/H1/Scripts/DARMOLGTFs/H1DARMOLGTFmodel_ER7.m with the following parameter set /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/PreER7/H1/Scripts/DARMOLGTFs/H1DARMparams_1116990382.m to produce a new Inverse Actuation Function for the HARDWARE Injection path, ultimately created by and plotted with /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/PreER7/H1/Scripts/DARMOLGTFs/CompareDARMOLGTFs.m The attached plots show bode plots of the design. As expected, because of the update to (a) the overall reduction of actuation scale factor (in [m/ct]), and (b) the frequency dependence of the actuation function to account for the new PUM / TST cross of ETMY, which is regrettably very feature full, the filter is significantly more complicated. The poles and zeros are toyModel.poles_Hz = [ pair(300,89.9) pair(300,89.9) pair(482,88.5) pair(1040,89.5) pair(3.2e3,0) pair(4e3,51) pair(6.5e3,60)]; toyModel.zeros_Hz = [0.01 0.01 pair(290,89) pair(310,88.9) pair(509,89.5) pair(1030,89.8) pair(3.2e3,70) 6.8e3]; The 300 [Hz] feature are the notches for the beam splitter violin mode (so we don't excite them via DARM), the ~500 and ~1000 [Hz] features are for the actual ETMY violin modes (which now leak through the L3 to L3 transfer function because of the inadequate roll off of the L2 to L3 transfer function), and the features at 2500, 3000, 3500, and 4000 [Hz] (which I did NOT both to include in the inverse filter) are to notch out further harmonics of the ETMY QUAD's violin modes. Finally, the > 4000 [Hz] poles are to roll-off the filter before the Nyquist frequency. The foton design string is zpk([0.01;0.01;5.0612+i*289.956;5.0612-i*289.956;5.95121+i*309.943;5.95121-i*309.943; 4.44181+i*508.981;4.44181-i*508.981;3.59537+i*1029.99;3.59537-i*1029.99;1094.46+i*3007.02; 1094.46-i*3007.02;6800],[0.523599+i*300;0.523599-i*300;0.523599+i*300;0.523599-i*300; 12.6173+i*481.835;12.6173-i*481.835;9.0756+i*1039.96;9.0756-i*1039.96;2517.28+i*3108.58; 2517.28-i*3108.58;3250+i*5629.17;3250-i*5629.17;3200;3200],1,"n")gain(1.27879e+09) where I've forced foton to use a gain of 1.14e17 [ct/m] at 100 [Hz], as shown in the plots, to avoid all the confusion about pole/zero normalization.