Displaying report 1-1 of 1.
Reports until 17:52, Friday 17 July 2015
H1 SUS (ISC)
nutsinee.kijbunchoo@LIGO.ORG - posted 17:52, Friday 17 July 2015 (19720)
Update to the complete violin mode study

A while ago I made a "complete" violin mode table here. Matt and Jeff was curious whether or not the frequencies belong to correct test mass. So, I went through the violin mode damping filters and see which one works and which doesn't. So far I was able to confirm that 24 out of 32 frequencies belong to the correct test masses. The filters were able to damp most of them. Three frequencies got rung up. The rest were still inconclusive (either the damping phases were off by 90 degrees or the test masses were wrong).

 

Frequency Test mass Filter Does the filter work? Note
         
500.054 ITMX MODE3 yes  
500.212   MODE3 yes  
501.092 ITMX MODE6 yes  
501.208   MODE3 yes  
501.254 ITMX MODE3 yes  
501.450   MODE3 yes  
502.621 ITMX MODE3 NO  
502.744   MODE3 yes  
         
503.007 ITMY MODE3 yes  
503.119   MODE1 yes  
504.803 ITMY MODE4 NO  
504.872   MODE4 yes  
501.606 ITMY MODE5 NO Rung up!
501.682   MODE5 yes  
501.749 ITMY MODE6 yes  
501.811   MODE6 NO  
         
507.992 ETMY MODE5 NO  
508.146   MODE5 yes  
508.010 ETMY MODE5 yes  
508.206   MODE5 yes  
508.220 ETMY MODE5 NO  
508.289   MODE5 NO  
508.585 ETMY MODE5 yes  
508.661   MODE5 NO  
         
505.587 ETMX MODE6 yes  
505.707   MODE6 NO  
505.710 ETMX MODE4 yes  
505.805   MODE4 NO Rung up!
506.922 ETMX MODE6 yes  
507.159   MODE6 yes  
507.194 ETMX MODE6 NO Rung up!
507.391   MODE6 yes  

 

Below is the table of the violin mode damping filters used by Guardian and the frequencies they (supposed to) damp:

w0 (Hz) wc (Hz) wc-w0 (Hz) Filter (All FM1) Test mass Frequency covered
506 513 7 MODE5 ETMY All ETMY
           
505.78 505.9 0.12 MODE4 ETMX 505.710, 505.805
502 520 18 MODE6 ETMX The rest of ETMX (cheater…)
           
485.7 506.4 20.7 MODE3 ITMX All ITMX
501.05 501.11 0.06 MODE6 ITMX 501.092
           
503.08 503.16 0.08 MODE1 ITMY 503.119
502.96 503.06 0.1 MODE3 ITMY 503.007
504.86 504.91 0.05 MODE4 ITMY 504.803, 504.872
501.63 501.7 0.07 MODE5 ITMY 501.606, 501.682
501.71 501.85 0.14 MODE6 ITMY 501.749, 501.811

 

Both tables are included in the excel file attached below.

Images attached to this report
Non-image files attached to this report
Displaying report 1-1 of 1.