Adjusted 35.9 Hz TST (ESD) line amplitude

RickS, Darkhan

We adjusted 35.9 Hz TST (L3 stage only) line drive level from 0.08 ct to 0.11 ct.

Now the amplitude of the TST calibration line in DARM_ERR readout is close to ampltitudes of 36.7 Hz Pcal and 37.3 Hz x_ctrl calibration lines. The target SNR for these lines and for 331.9 Hz Pcal line is 100 SNR with 10 s FFTs (see T1500377).