Zoomed-in noise budget from 2015-10-24

GWINC quantum noise curve is replaced with dynamically-generated shot noise curve. Radiation pressure will be included later.

The null stream spectrum shows 8×10−8 mA/rtHz shot noise, which seems to imply 17 mA of dc photocurrent on the sum, rather than the expected 20 mA.

Non-image files attached to this report
Comments related to this report
evan.hall@LIGO.ORG - 08:56, Friday 13 November 2015 (23371)

Matt, Evan

The attachment shows two simple power-law curves (1/f2 and 1/f2.5) superimposed by eye on the residual. At first glance it is not clear which fits better.

In the case of 1/f2, we are looking for something that makes a white force noise on the bottom stage of a suspension (e.g., white electronics noise).

In the case of 1/f2.5, we are potentially looking at something less mundane; e.g., a force noise that goes like 1/f0.5, or potentially elevated structural loss on some suspension.