The FAMIS procedure notes the normal operating range for the oplevs is +/- 10urad (but some can still operate normally beyond this). I'm assuming the count values in dataviewer are in urad. Attached are the pit, yaw, & sum 7-day trends.
Notes:
-
PIT: ETMx, ETMy, ITMx, & ITMy are beyond the +/- 10urad operating range, and may require re-zeroing soon.
-
YAW: ETMx, ITMx, ITMy, PR3, & HAM2 are beyond the +/- 10urad operating range, and may require re-zeroing soon.
-
SUM: Procedure does not give operating range values for SUMs, but just looking at the 7-day trend, the only oddity is that SR3 has an odd 3-day step up. Could this be blamed on the HAM6 vent nearby? Looking back 37-days, see a couple of these steps up over the last few weeks.
This closes out FAMIS #4670.