HWSY measurements of spherical power - glitches and apparent excess CO2 spherical power

Summary:

I analyzed the HWSY measurements from a ~28 hour period around the 18th of May during a long lock segment and lock/unlocked transitions. There are systematic shifts in the measured defocus which can only be coming from some alignment coupling. There is evidence that the delivered CO2 laser power may be more than the CO2Y power meter suggests.

Our attempts to maintain the total lens using the CO2 laser power during locked/unlocked transitions are currently ineffective because the CO2-induced thermal lens response is not calibrated correctly.

Analysis:

There was as a period of a 7 hour lock last week. I extracted the RAW HWS images corresponding to this period (t0 = 1147500000 to t0 + 1E5s) from the directory: controls@h1hwsmsr:~/framearchive/h1hwsmsr/ITMY/1147500000/. These were centroided offline to determine the measured defocus (a proxy for H1:TCS-ITMY_HWS_PROBE_SPHERICAL_POWER which should be running online). The offline calibration included:

I also extracted the SIM estimates of defocus (defocii?) from the self-heating (H1:TCS-SIM_ITMY_SUB_DEFOCUS_SELF_OUTPUT) and CO2 laser power (H1:TCS-SIM_ITMY_SUB_DEFOCUS_SELF_OUTPUT). All three of these time series are plotted below.

And a zoomed version of the first 600 minutes is shown below:

 

A few points to note:

If I double the expected CO2 response and create a new channel that is the sum of the double CO2 lens and the SELF heating (and reset the zero value of this channel), I get a result that is much closer to the measured lens in the HWS.

 

Additionally:

As you can see in the images attached to aLOG 27047,  that CO2Y table is capable of delivering a maximum of ~2.3W off the table (when the CO2Y laser is running at 57W). The CO2X table is capable of delivering a maximum of ~5.5W off the table (when the CO2X laser is running at 59W). There is no functional difference in the design of the two tables (expect that Y is a mirror image of X). The possibilities for this difference are:

And: the maximum power that could be delivered from this table on 26-Jan-2016 was around 5.5W.

Therefore: Given all this information, I suspect that the CO2 laser is somehow reading back less power than it is delivering (or, if you like, delivering more power than we're expecting).

TO DO: