sheila.dwyer@LIGO.ORG - posted 20:07, Saturday 28 May 2016 - last comment - 14:08, Friday 03 June 2016(27437)
locklosses possibly related to RF problem or SR3 glitches

Evan and I spent most of the day trying to investigate the sudden locklosses we've had over the last 3 days.  

1) We can stay locked for ~20 minutes with ALS and DRMI if we don't turn on the REFL WFS loops.  If we turn these loops on we loose lock within a minute or so.  Even with these loops off we are still not stable though, and saw last night that we can't make it through the lock acquisition sequence. 

2)In almost every lockloss, you can see a glitch in SR3 M2 UR and LL noisemons just before the lockloss, which lines up well in time with glitches in POP18.  Since the UR noisemon has a lot of 60 Hz noise, the glitches can only be seen there in the OUT16 channel, but the UR glitches are much larger.  (We do not actuate on this stage at all).  However, there are two reasons to be skeptical that this is the real problem:

It could be that the RF problem that started in the last few days somehow makes us more senstive to loosing lock because of tiny SR3 glitches, or that the noisemons are just showing some spurious signal which is related to the lockloss/ RF problems. Some lockloss plots are attached. 

It seems like the thing to do would be trying to fix the RF problem, but we don't have many ideas for what to do. 

Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 20:25, Saturday 28 May 2016 (27438)

We also tried running the Hang's automatic lockloss tool, but it is a little difficult to interpret the results from this.  There are some AS 45 WFS channels that show up in the third plot that apprears, which could be related to either a glitchy SR3 or an RF problem. 

Images attached to this comment
sheila.dwyer@LIGO.ORG - 20:27, Saturday 28 May 2016 (27439)

One more thing: Nnds1 chrashed today and Dave helped us restart it over the phone.

andrew.lundgren@LIGO.ORG - 07:41, Wednesday 01 June 2016 (27470)DetChar, ISC, Lockloss
For the three locklosses that Sheila plotted, there actually is something visible on the M3 OSEM in length. It looks like about two seconds of noise from 15 to 25 Hz; see first plot. There's also a huge ongoing burst of noise in the M2 UR NOISEMON that starts when POP18 starts to drop. The second through fourth attachments are these three channels plotted together, with causal whitening applied to the noisemon and osem.

Maybe the OSEM is just witnessing the same electrical problem as is affecting the noisemon, because it does seem a bit high in frequency to be real. But I'm not sure. It seems like whatever these two channels are seeing has to be related to the lockloss even if it's not the cause. It's possible that the other M2 coils are glitching as well. None of the other noisemons look as healthy as UR, so they might not be as sensitive to what's going on.
Images attached to this comment
keita.kawabe@LIGO.ORG - 14:08, Friday 03 June 2016 (27501)

RF "problem" is probably not a real RF problem.

Bad RFAM excess was only observed in out-of-loop RFAM sensor but not in the RFAM stabilization control signal. In the attached, top is out-of-loop, middle is the control signal, and the bottom is the error signal.

Anyway, whatever this low frequency excess is, it should come in after the RF splitter for in- and out-of-loop board. Since this is observed both in 9 and 45MHz RFAM chassis, it should be in the difference in how in- and out-of-loop boards are configured. See D0900761. I cannot pinpoint what that is but my guess is that this is some DC stuff coming into the out-of-loop board (e.g. auto bias adjustment feedback which only exists in out-of-loop).

Note that even if it's a real RFAM, 1ppm RIN at 0.5Hz is nothing assuming that the calibration of that channel is correct.

Images attached to this comment
andrew.lundgren@LIGO.ORG - 15:22, Wednesday 01 June 2016 (27486)DetChar, ISC, Lockloss
Correction: The glitches are visible on both the M2 and M3 OSEMs in length, also weakly in pitch on M3. The central frequency looks to be 20 Hz. The height of the peaks in length looks suspiciously similar between M2 and M3.
Images attached to this comment
andrew.lundgren@LIGO.ORG - 01:42, Thursday 02 June 2016 (27496)DetChar, ISC, Lockloss
Just to be complete, I've made a PDF with several plots. Every time the noise in the noisemons comes on, POP18 drops and it looks like lock is lost. There are some times when the lock comes back with the noise still there, and the buildup of POP18 is depressed. When the noise ends, the buildup goes back up to its normal value. The burst of noise in the OSEMs seems to happen each time the noise in the noisemons pops up. The noise is in a few of the noisemons, on M2 and M3.