corey.gray@LIGO.ORG - posted 10:35, Tuesday 28 June 2016 - last comment - 10:52, Tuesday 28 June 2016(28005)
Test Mass & HAM Oplevs vs Locklosses

Last week, Rana was inquiring about how locklosses affect oplev sums. 

Took a random sample of locklosses from O1 and came up with fairly consistent results for after a lockloss, so here's the nitty gritty:

Attached is an example of a lockloss from Nov.

Non-image files attached to this report
Comments related to this report
keita.kawabe@LIGO.ORG - 10:52, Tuesday 28 June 2016 (28006)

There's a DCC document and even a tool to look at these things.

https://dcc.ligo.org/LIGO-T1600085