Displaying report 1-1 of 1.
Reports until 11:04, Friday 12 August 2016
H1 ISC (ISC, Lockloss)
richard.mccarthy@LIGO.ORG - posted 11:04, Friday 12 August 2016 - last comment - 08:17, Monday 15 August 2016(29059)
Modifications to ISC rack and Fast Shutter near Ham6
In an effort to eliminate the need to connect and disconnect shutter cables during vent we have moved the shutter logic controler to the rack from the table.  Also replaced the BNC cables with Yellow BNC cables so they can be easily identified.
See attachment.
Non-image files attached to this report
Comments related to this report
daniel.sigg@LIGO.ORG - 08:17, Monday 15 August 2016 (29099)

Drawings D1200196 and D1201500 updated.

Displaying report 1-1 of 1.