TCS power stabilization guardian unlocking multiple times

Sheila and Jenne informed me that the TSC ITMY CO2 guardian suddenly had changed its state this evening, kicking us out of the observing mode

I trended some relevant data and checked the guardian logs. It seems that since the upgrade of the guardian machine this morning (32072), the TCS CO2 guardians for both X and Y arms unlocked multiple times for some reason. The first attachment is the trend of some relevant channels for this past 12 hours. As shown in the upper panels, the guardians changed their states multiple times in the past hours due to the lasers unlocked. Reading the guardian logs (which are attached) and codes, these events were indentified to be due to the PZT output signals exceeding some thresholds that are set in the guardian codes. This had not happened in the past four or five days until this morning. The number of incidents seems to decrease as a function of time. I am hoping that the CO2 lasers will eventually settle to some kind of stable point in which the guardians don't need to change the state any more.

 

For operators,

If this happens again (which should be obvious as it flips the intent bit back to commissioning), please follow the following procedure.

Images attached to this report
Non-image files attached to this report
Comments related to this report
kiwamu.izumi@LIGO.ORG - 18:20, Thursday 01 December 2016 (32092)

Additionally, the attached is a magnified version of the trend focusing on the last incident. Initially the laser power dropped monotonically in sync with the PZT output signal which was monotonically increasing. Then the PZT signal crossed the upper threshold of 70 counts which was detected by the guardian. Subsequently the guardian switched its state to something else. Finally this change in the guardian state was detected by the IFO guardian who lowered the intent bit to commissioning.