Displaying report 1-1 of 1.
Reports until 16:12, Tuesday 21 March 2017
H1 CAL
jeffrey.kissel@LIGO.ORG - posted 16:12, Tuesday 21 March 2017 - last comment - 10:50, Tuesday 04 April 2017(34984)
2017-03-21 New Calibration Sensing Function Measurement Suite
J. Kissel

I've gathered our "bi-weekly" calibration suite of measurements to track the sensing function, and ensure all calibration is within reasonable uncertainty and to have corroborating evidence for a time-dependent detuning spring frequency & Q. Trends of previous data have now confirmed time dependence -- see LHO aLOG 34967.

Evan is processing the data and will add this day's suite to the data collection.

We will begin analyzing the 7.93 Hz PCAL line that's been in place since the beginning of ER10, using a method outlined in T1700106, and check the time dependence in a much more continuous fashion. My suspicion is that the SRC detuning parameters will change on the same sort of time scale as the optical gain and cavity pole frequency.

Note also, that I've grabbed a much longer data set for the broad-band injection, as requested by Shivaraj -- from 22:50:15 UTC to 22:54:20 UTC, roughly 4 minutes.

The data have been saved and committed to:
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O2/H1/Measurements/SensingFunctionTFs
    2017-03-21_H1DARM_OLGTF_4to1200Hz_25min.xml
    2017-03-21_H1_PCAL2DARMTF_4to1200Hz_8min.xml

    2017-03-06_H1_PCAL2DARMTF_BB_5to1000Hz_0p25BW_250avgs_5min.xml
The data have been exported with similar names to the same location in the repo.

For time-tracking, this suite took ~38 minutes from 2017-03-21, 22:18 - 22:56 UTC.
Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 17:37, Tuesday 21 March 2017 (34987)CAL, DetChar, GRD, ISC
J. Kissel

Because the calibration suite requires one to turn OFF all calibration lines before the measurements then back ON after, the time-dependent correction factor computation is spoiled temporarily. In the GDS pipeline, which uses FIR filters, it takes about 2 minutes for the calculation to return to normal functionality and produce sensible results (Good! this is what's used to correct h(t)). However, because the front-end's version of this calculation (NOT used in any corrections of any astrophysical or control room product) uses IIR filters, it remains polluted until one manually clears the history on all filter banks involved in the process. 

Normally, as the ISC_LOCK guardian runs through the lock acquisition sequence, it clears these filter banks history appropriately. However, the calibration suite configuration is still a manual action.

Moral of the story -- I'd forgotten to do this history clearing until about 1 hr into the current observation stretch. The history was cleared at approximately  2017-03-22 00:10 UTC.

Why am I aLOGging it? Because clearing this history does NOT take us out of observation mode. Rightfully so in the case, because again the front-end calculation is not yet used in any control system, or to correct any data stream, it is merely a monitor. I just aLOG it so that the oddball behavior shown at the tail end of today's UTC summary page has an explanation (both 20170321 and 20170322 show the effect).

To solve this problem in the future, I'm going to create a new state in the ISC_LOCK guardian that does the simple configuration switches necessary so no one forgets in the future.
Images attached to this comment
jeffrey.kissel@LIGO.ORG - 18:48, Tuesday 21 March 2017 (34991)CAL, ISC
J. Kissel

On the discussion of "Why Can't LLO the same SNR / Coherence / Uncertainty below 10 Hz for These Sensing Function Measurements?"

It was re-affirmed by Joe on Monday's CAL check-in call that LLO cannot get SNR on 5- 10 Hz data points. There are two things that have been investigated that could be the reason for this:
   (1) The L1 DARM Loop Gain is too large ("much" larger than H1) at these frequencies, which suppresses the PCAL and SUS actuator drive signals.
   (2) Because of L1's choice in location of applying the optical plant's DC readout DARM offset and avoiding-DAC-zero-crossing-glitching SUS offset means there are single vs. double precision problems in using a very traditional DARM_IN1/DARM_IN2 location of the open loop gain transfer function.
both investigations are described in LHO aLOG 32061.

They've convinced me that (2) is a small effect, and the major reason for the loss in SNR is the loop gain. However, Evan G. has put together a critique of the DARM loop (see G1700316), which shows that the difference in suppression between 5-10 Hz is only about a factor of 4. I put a screen cap of page 4 which shows the suppression.

I attach a whole bunch of supporting material that shows relevant ASDs for both during the lowest frequency points of the DARM OLG TF and the PCAL 2 DARM TF:
     - DACRequest -- shows that a factor of 4 increase in drive strength would not saturate any stage of the ETMY suspension actuators
     - SNR_in_DARM_ERR -- shows the loop suppressed SNR of the excitation
     - SNR_in_DELTAL_EXT -- shows the calibrated displacement driven
     - SNR_in_OMC_DCPDs -- shows that a factor of 4 increase in drive strength would not saturate the OMC DCPDs 

 So ... is there something I'm missing?
Images attached to this comment
shivaraj.kandhasamy@LIGO.ORG - 09:39, Tuesday 28 March 2017 (35134)

Here with attached a plot showing comparison of PCal, CAL-DELTAL_EXTERNAL and GDS for the broad band injection. As expected, GDS agrees better with PCal injection signal. The code used to make the plot is added to svn,

/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O2/H1/Scripts/PCAL/PcalBroadbandComparison20170321.m
Images attached to this comment
jeffrey.kissel@LIGO.ORG - 10:39, Tuesday 28 March 2017 (35135)
Just to close out the question in Comment #2 above, LLO was indeed able to use LHO-like templates and drastically improve their SNR at low-frequency; check out LLO aLOG 32495. 

Hazaah!
jeffrey.kissel@LIGO.ORG - 10:50, Tuesday 04 April 2017 (35311)
J. Kissel, E. Goetz

The processed results for this data set are attached.

For context of how this measurement fits in with the rest of measurements taken during ER10 / O2, check out LHO aLOG 35163.
Non-image files attached to this comment