Blend Filters were refined on ITMY. The current state is: 750 mHz in Stage 1 RX and RY 250 mHz in Stage 2 All dofs, and Stage 1 X, Z, RZ 100 mHz on Stage 1 Y The plot attached shows the latest isolation results (Red is Damped, Blue is Isolated). We are converging toward a configuration that we should be able to copy/paste on other units. Otherwise, I was having to turn the loops in the low blend configuration. The "boost" filters were making glitches in the actuators output, tripping the watch dogs. I modified the output compensation filters to filter out the glitches. The turn on/off process is now smooth and do not trip the watchdogs anymore.