Reports until 00:00, Tuesday 04 July 2017
H1 CAL (CAL, DetChar)
cheryl.vorvick@LIGO.ORG - posted 00:00, Tuesday 04 July 2017 - last comment - 12:56, Tuesday 11 July 2017(37304)
H1 kicked out of Observe
Images attached to this report
Comments related to this report
paul.marsh@LIGO.ORG - 14:09, Monday 10 July 2017 (37423)
CW GAIN issue has been resolved. The CW_GAIN and CW_TRAMP values were being monitored by Guardian, which forced the IFO out of observing when those values changed; those values were changed due to a loss of hardware injections and subsequent restart by the psinject script. Dave Barker and I have changed the gain and ramp to be unmonitored channels again.

Notes attached.
Non-image files attached to this comment
paul.marsh@LIGO.ORG - 12:56, Tuesday 11 July 2017 (37450)
Change undone after the decision was made that losing IFO lock was the desired behavior and issue was mitigated by sparse nature of psinject reset. See aLOG 37447.