Displaying report 1-1 of 1.
Reports until 16:59, Thursday 13 September 2012
X1 SUS
jeffrey.bartlett@LIGO.ORG - posted 16:59, Thursday 13 September 2012 - last comment - 20:00, Thursday 13 September 2012(4195)
Phase 1b Testing H1-PRM
We have taken the Phase 1b transfer functions and power spectra for H1-PRM. 
The files from 09/06 are for undamped Transfer functions.
The files from 09/10 are for damped Transfer functions. 
The files from 09/13 are for the damped and undamped power spectra. 

Non-image files attached to this report
Comments related to this report
stuart.aston@LIGO.ORG - 20:00, Thursday 13 September 2012 (4196)
For a comparison of all Phase 1b HSTS M1-M1 transfer functions obtained so far, for both LLO & LHO, see plots below:-

- allhstss_2012-09-13_2100_All_Phase1b_HSTSs_ALL_TFs.pdf
- allhstss_2012-09-13_2100_All_Phase1b_HSTSs_ALL_ZOOMED_TFs.pdf

Also, I noted that one of the power spectra plots was missing:-

- 2012-09-13_1230_X1SUSPRM_M1_ALL_Spectra.pdf


Non-image files attached to this comment
Displaying report 1-1 of 1.