IMC Error Signal Spike at 53.4 kHz
I took an IMC spectrum at the MC servo board while ALS_COMM and CARM have been down today.  There's a spike at 53.4 kHz.  Not clear to me what's causing this.

Edit: It's gain peaking.  Attached IMC OLG.  Adjusted IMC_power_adjust_func() in ISC_library.py to give 3 dB less gain and put the IMC UGF at around 25 kHz where we have heaps of phase margin.
Non-image files attached to this report
Comments related to this report
craig.cahillane@LIGO.ORG - 20:28, Tuesday 04 September 2018 (43828)
I actually brought the IMC servo board IN1 Gain down 6 dB (from 23 dB to 17 dB at 2 watts input power) because there was still significant peaking with a 3 dB reduction.
New IMC spectrum/OLG posted.  

IMC UGF = 21 kHz

This low of frequency suppression could have implications down the road, from direct coupling to DARM to vertex LSC noise coupling.  More quantitative statements are forthcoming.