J. Kissel, J. Driggers In prep for the ISC triggering shut offs, as well as a change in configuration to the dolphin network, all suspension models will need to be restarted today. As such, I've reconciled all suspensions safe.snap SDF files. I attach a full detail of what I've accepted / reverted, but aside from capturing the latest alignment offsets, the only suspensions that had major changes that needed reconciling were the QUADs -- ETMX, ETMY, ITMX, ITMY. With the help of Jenne, we did our best to accept or revert changes on those suspensions that were related to the past ~week's worth of commissioning.
ITMY "- accepting violin mode matrix 2_11 from 0.0 to 1.0 - accepting turning on mode 11, and several phase tuning filters." Also from violin mode damping work.
"- Violin mode matrix 02_20 from 1.0 set to zero (controlled by guardian?)" This was probably from the violin mode damping I was working on last night. I have been using mode 20 as a test filter module.
The one weird thing that I wasn't sure of, was the TRAMPs for ASC-AS_A_RF45 I and Q segments 1-4. I'm not sure why those were set to 30sec, but I reverted them to 0sec.