Displaying report 1-1 of 1.
Reports until 10:54, Tuesday 06 November 2018
H1 SUS (CAL, CDS, ISC)
jeffrey.kissel@LIGO.ORG - posted 10:54, Tuesday 06 November 2018 - last comment - 11:48, Tuesday 06 November 2018(45047)
SDF (safe) files reconciled for all SUS
J. Kissel, J. Driggers

In prep for the ISC triggering shut offs, as well as a change in configuration to the dolphin network, all suspension models will need to be restarted today. As such, I've reconciled all suspensions safe.snap SDF files. I attach a full detail of what I've accepted / reverted, but aside from capturing the latest alignment offsets, the only suspensions that had major changes that needed reconciling were the QUADs -- ETMX, ETMY, ITMX, ITMY. With the help of Jenne, we did our best to accept or revert changes on those suspensions that were related to the past ~week's worth of commissioning.
Non-image files attached to this report
Comments related to this report
patrick.thomas@LIGO.ORG - 11:47, Tuesday 06 November 2018 (45053)
ITMY
"- accepting violin mode matrix 2_11 from 0.0 to 1.0
- accepting turning on mode 11, and several phase tuning filters."

Also from violin mode damping work.
patrick.thomas@LIGO.ORG - 11:43, Tuesday 06 November 2018 (45052)
"- Violin mode matrix 02_20 from 1.0 set to zero (controlled by guardian?)"

This was probably from the violin mode damping I was working on last night. I have been using mode 20 as a test filter module.
jenne.driggers@LIGO.ORG - 11:48, Tuesday 06 November 2018 (45054)

The one weird thing that I wasn't sure of, was the TRAMPs for ASC-AS_A_RF45 I and Q segments 1-4.  I'm not sure why those were set to 30sec, but I reverted them to 0sec.

Displaying report 1-1 of 1.