Reports until 23:04, Wednesday 05 December 2018
H1 ISC
sheila.dwyer@LIGO.ORG - posted 23:04, Wednesday 05 December 2018 - last comment - 09:21, Thursday 06 December 2018(45720)
summary of noise tests this evening

After getting the interferometer locked again we had a productive afternoon and evening.  

Images attached to this report
Non-image files attached to this report
Comments related to this report
gabriele.vajente@LIGO.ORG - 09:21, Thursday 06 December 2018 (45743)

A BruCO scan is available at https://ldas-jobs.ligo-wa.caltech.edu/~gabriele.vajente/bruco_lho_1228085658/

Some coherences at first glance, none of them super high (but maybe non stationary?)

  • CHARD_P and CHARD_Y below 15 Hz
  • SRCL between 40 and 200 Hz
  • MICH between 10 and 70 Hz
  • PRCL between 20 and 200 Hz
  • ASC-OMC_A_PIT / OMC_M1_AC_P_IN1 / ASC-DC3_P_OUT between 20 and 30 Hz
  • PEM-EX_MAG_EBAY_SUSRACK_Z at many narrow frequencies
Images attached to this comment