some squeezer acoustic coupling tests, attempt at seeding and backscatter check

Robert, Sheila, Nutsinee

Better alogs will be coming with details, but earlier this evening we spent some time doing squeezing tests.  From about 20:50 UTC to 23:50 UTC (including time when IFO unlocked and was relocked), Nutsinee did measurements of squeezing and anti-squeezing for three different nonlinear gains.  

From 23:50 UTC Dick went into the CER to do a couple of tests, the IFO lost lock during this time.  

After relocking Robert and I did some test of the acoustic coupling from ISCT6.  Robert has more details, but some main points are:

We attempted to do the measurement where we offset the squeezer laser frequency from the PSL to see the two lumps in darm from backscatter and seeding.  The squeezer laser is moving too much relative the the PSL to do this measurement.  We could probably make this better by implementing the IMC VCO FF, or if we used a pick off that isn't in the ref cav path as they do at LLO we wouldn't have as much motion.  

Comments related to this report
robert.schofield@LIGO.ORG - 08:38, Friday 15 March 2019 (47557)

Figure attached showing coupling variation with different squeezer settings

Non-image files attached to this comment