At the request of Dave and Besty, I've used Joe and Adam's Instructions to building SUS infrastructure from scratch (supplemented by more stuff by me) to fill in everything* needed for H1 SUS ITMY, including all filters and EPICs values, using H1 SUS ETMY as my starter QUAD. Note that I've changed EPICs values that are not common to each QUAD, namely:
- Zeroed out alignment offsets
- Installed correct ISI<->SUS projection matrices for H1 SUS ITMY
- Zeroed out non-diagonal DRIVEALIGN matrix elements.
After which I've saved a safe.snap, which lives here:
/opt/rtcds/userapps/release/sus/h1/burtfiles/itmy/h1susitmy_safe.snap
Attached is a detailed log of my actions, such that they might be turned into a script one day, if not at least used to fill out the wiki instructions...
* "Everything" excludes correct optical lever calibration gains, and OSEMINF open light offsets and gains, which need to be measured and installed when possible.