CLF/LO readbacks follow-up

Following up on alog 48180 and the changes we did to the common mode readback channels, we find significant improvements in the spectra of CLF and LO.  There is still limited coherence below ~10 Hz between most channels. Some of it is due to quantization noise, but at least for the ERR readback, it may still be slew rate limitations.