Displaying report 1-1 of 1.
Reports until 08:19, Friday 14 June 2019
H1 AOS
cheryl.vorvick@LIGO.ORG - posted 08:19, Friday 14 June 2019 (49912)
changes between this lock and last

I ran my matlab code to look at two times, one during this lock, and one from the previous lock, to identify changes. Attached are results, in list form, from the excel file and in plots where the blue trace is from the previous lock and the red trace is from the current lock. 

channel   start end diff abs(diff)
H1:SUS-OMC_M1_DAMP_P_INMON p 1323.2684 1276.9399 -46.3284 46.3284
H1:SUS-PRM_M3_WIT_PMON p -1627.9656 -1581.6614 46.3043 46.3043
H1:SUS-SRM_M3_WIT_PMON p 2300.4584 2322.5835 22.1252 22.1252
H1:SUS-ZM1_M1_DAMP_P_INMON p -2407.8339 -2416.8431 -9.0092 9.0092
channel   start end diff abs(diff)
H1:SUS-SRM_M1_DAMP_Y_INMON y -1862.5385 -1887.4435 -24.9049 24.9049
H1:SUS-SRM_M3_WIT_YMON y -3533.2723 -3546.7958 -13.5235 13.5235
H1:SUS-SR2_M3_WIT_YMON y -219.2685 -225.0900 -5.8215 5.8215
Images attached to this report
Non-image files attached to this report
Displaying report 1-1 of 1.