Reports until 18:56, Tuesday 19 November 2019
H1 ISC (ISC, SUS)
sudarshan.karki@LIGO.ORG - posted 18:56, Tuesday 19 November 2019 - last comment - 11:33, Monday 25 November 2019(53378)
A2A to DARM Measurement

[Sudarshan, Sheila]

We made two transfer function measurements between the  A2A  L2 drive align filter and DARM  with beam spot centered and beam spot moved at 2 watts input power. We drove only in Pitch. These measurments were done in an effort to understand the angle to length coupling of PUM stage. We will compare these measurements with the models to see how well they agree. The screenshot of the transfer function is attached below. Model comparison to follow soon.

 

Images attached to this report
Comments related to this report
sudarshan.karki@LIGO.ORG - 11:33, Monday 25 November 2019 (53480)ISC

[Sudarshan, Sheila, MattB]

The attached plot shows the comparison between the measurement, made above, and a model. The measurment seem to agree pretty well with the model in magnitude. There is some phase discrepancy, about 20 deg. at 20 Hz, between the measurement and the model. We don't yet understand why. P.S. The green shade on the plot is the frequency regime where the injections were made to make this measurement.

Non-image files attached to this comment