Reports until 12:34, Monday 24 May 2021
H1 ISC
daniel.sigg@LIGO.ORG - posted 12:34, Monday 24 May 2021 (59058)
Sideband Power Levels

We are analyzing the data taken with different modulation indices described in alog 58946 to get the different RF field components at each detector port. The analysis uses the known modulation indices (alogs 41889 and 41435) and their change to deduce the amount of 9 MHz RF sidebands, 45 MHz RF sidebands and carrier. A previous determination before the ITM was swapped can be found in alog 48595. See the attached nb file for details.

The table below lists the fractional contribution of each RF component in units of percent power. The columns with the tag "dec" were measured by decreasing the modulation depth, whereas "inc" indicates increased modulation depth. The precision is 0.1% at best, but the AS port measurements are far less consistent.

Port              DC 45 MHz dec 45 MHz inc 9 MHz dec 9 MHz inc Carrier dec Carrier inc
Input power (W) 45.8 1.66 1.67 0.87 0.87 97.5 97.5
REFL_A (mW) 18.1 4.3 4.3 5.7 5.7 90.0 90.0
REFL_B (mW) 16.7 4.3 4.2 5.6 5.7 90.1 90.1
POP_LF (cnt) 50725 0.17 0.22 1.7 1.7 98.1 98.1
POP_A_NSUM (cnt) 6045 0.20 0.34 1.6 1.6 98.2 98.0
POP_B_NSUM (cnt) 5493 0.24 0.29 1.7 1.7 98.0 98.1
AS_C_NSUM (mW) 320 85.7 84.0 1.7 1.6 12.6 14.5
OMC_A_NSUM (mW) 305 87.7 85.9 1.6 1.5 10.7 12.7
OMC_B_NSUM (mW) 314 90.5 88.6 1.5 1.4 8.0 10.0
TR_X_A (kcnt) 270 <0.2 <0.2 <0.2 <0.2 100 100
TR_X_B (kcnt) 352 <0.2 <0.2 <0.2 <0.2 100 100
TR_Y_A (kcnt) 364 <0.2 <0.2 <0.2 <0.2 100 100
TR_Y_B (kcnt) 385 <0.2 <0.2 <0.2 <0.2 100 100

The measurements on the input power are consistent with the estimated modulation indices. It is unclear why the 45 MHz contributions measured at the dark port vary by up to 5%.

Performing the same analysis for the April 2019 measurements we get the table below. Back then, only a modulation depth increase was performed.

Port       DC 45 MHz 9 MHz Carrier
Input power (W) 35.4 1.67 0.88 97.5
REFL_A (mW) 5.3 14.0 3.6 82.4
REFL_B (mW) 4.9 13.9 3.6 82.5
POP_LF (cnt) 32137 0.36 1.2 98.5
POP_A_NSUM (cnt) 3871 0.39 1.2 98.5
POP_B_NSUM (cnt) 3555 0.40 1.2 98.4
AS_C_NSUM (mW) 245 70.0 9.0 21.4
OMC_A_NSUM (mW) 226 75.3 8.0 16.7
OMC_B_NSUM (mW) 221 80.1 6.3 13.6
TR_X_A (kcnt) 173 <0.1 <0.1 100
TR_X_B (kcnt) 226 <0.1 <0.1 100
TR_Y_A (kcnt) 247 <0.1 <0.1 100
TR_Y_B (kcnt) 262 <0.1 <0.1 100

Finally, we are going to compare the new and old measurements by first scaling for the input power and then taking the power ratios of new over old.

Port      DC 45 MHz 9 MHz Carrier
Input power 1 1 0.98 1
REFL_A 2.64 0.81 4.2 2.88
REFL_B 2.65 0.81 4.2 2.89
POP_LF 1.22 0.74 1.77 1.22
POP_A_NSUM 1.21 1.07 1.69 1.20
POP_B_NSUM 1.20 0.85 1.71 1.19
AS_C_NSUM 1.00 1.22 0.29 0.68
OMC_A_NSUM 1.04 1.19 0.24 0.79
OMC_B_NSUM 1.10 1.22 0.24 0.81
TR_X_A/B 1.21 1.21
TR_Y_A/B 1.14 1.14

Conclusions from these measurements:

Non-image files attached to this report