betsy.weaver@LIGO.ORG - posted 10:34, Wednesday 10 November 2021 (60603)
OFI TFs after mech interference was alleviated

Attached are the PDFs of transfer functions TJ and I ran yesterday after we found and corrected the mechanical rubbing on the OFI in Yaw.  The ISI was locked during these measurements.

/ligo/svncommon/SusSVN/sus/trunk/OFIS/H1/OFI/SAGM1/Data

2021-11-09_2217_H1SUSOFI_M1_WhiteNoise_Y_0p01to50Hz.xml

2021-11-09_2217_H1SUSOFI_M1_WhiteNoise_T_0p01to50Hz.xml

2021-11-09_2217_H1SUSOFI_M1_WhiteNoise_L_0p01to50Hz.xm