IM4 Trans centered
Because of high measured jitter coupling from alog 64372,
we are interested in the IM4 Trans input beam jitter witness.

We also recently engaged a stage of whitening to avoid ADC noise, but found we are dark noise limited on this diode alog 64371.

I moved the PICO B  (HAM 2 + oplev) motor 2 (IO IM4_Trans QPD centering) down and to the left, relative position change from (X = 0, Y = 0) to (X = 3700, Y = -3880) 

This increased the witnessed power on IM4 Trans by 0.4%.  
We don't want this to overwrite our IM4 calibration from alog 63812, 
so I adjusted the Input beam power incident on PRM calibration (IM4 Trans NSUM FM10 gain) from 4.624 to 4.606.
Images attached to this report
Comments related to this report
craig.cahillane@LIGO.ORG - 23:29, Thursday 11 August 2022 (64450)
IM4 segments after realignment posted, for comparison to alog 64378.

Some strange shelf is occurring around 7 Hz here, obscuring the peak Evan's spectra saw, may be spectral leakage.  Forest of peaks at 13 and 18 Hz appear again.

We can grab a long spectra from today's lock to resolve these peaks and limit leakage.
Non-image files attached to this comment
craig.cahillane@LIGO.ORG - 16:57, Friday 12 August 2022 (64467)
Uploaded finer resolution spectrum.  
Non-image files attached to this comment