J. Kissel, E. Capote Elenna and I characterized the "global actuation" transfer functions, i.e. each actuation stage drive to optic response, or M3 to M3, M2 to M3, and M1 to M3, for two HSTSs today, PRM and SRM. We gathered these TFs with the former damping loops (which we've again reverted to as of Jan 26 2023; LHO:67031), and with the "level 2" damping loops (installed, commissioned, and tried last on Jan 18 2023; LHO:66859) in hopes to better understand and either prove or disprove to ourselves that the damping loop change impacts the ISC loops in L, P, and Y, that are wrapped around them. It's too much data to process coherently, and we don't yet have a complete set, so here I only document that we performed the measurement, and where the data is saved. For future reference, - PRM was ALIGNED, with alignment offsets ON - SRM was MISALIGNED with *misalignement* offsets ON - For both SUS, we had the M1, M2, and M3 coil drivers in state 1, 2, and 2, respectively. The data has been committed to the SVN here: PRM M1: /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PRM/SAGM1/Data/ 2023-02-07_1824_H1SUSPRM_M1_M3_CDBIOState_1_L_0p03to50Hz_new_and_old.xml 2023-02-07_1824_H1SUSPRM_M1_M3_CDBIOState_1_P_0p03to50Hz_new_and_old.xml 2023-02-07_1824_H1SUSPRM_M1_M3_CDBIOState_1_Y_0p03to50Hz_new_and_old.xml (REF traces are with old M1 DAMP damping filters, live trace is with new Level 2 filters) PRM M2: /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PRM/SAGM2/Data/ 2023-02-07_1940_H1SUSPRM_M2_M3_CDBIOState_2_L_0p03to50Hz_new_damping.xml 2023-02-07_1940_H1SUSPRM_M2_M3_CDBIOState_2_P_0p03to50Hz_new_damping.xml 2023-02-07_1940_H1SUSPRM_M2_M3_CDBIOState_2_Y_0p03to50Hz_new_damping.xml (REF traces are with old M1 DAMP damping filters, live trace is with new Level 2 filters) PRM M3: /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PRM/SAGM2/Data/ 2023-01-24_1840_H1SUSPRM_M3_WhiteNoise_CDBIOState_1_L_0p03to50Hz.xml # actually in State 1, unlike what's said above 2023-01-24_1840_H1SUSPRM_M3_WhiteNoise_CDBIOState_1_P_0p03to50Hz.xml 2023-01-24_1840_H1SUSPRM_M3_WhiteNoise_CDBIOState_1_Y_0p03to50Hz.xml (REF traces are with old M1 DAMP damping filters, live trace is with new Level 2 filters) SRM M3: /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/SRM/SAGM3/Data/ 2023-02-07_1828_H1SUSSRM_M3_WhiteNoise_L_0p03to50Hz_ODF.xml 2023-02-07_1828_H1SUSSRM_M3_WhiteNoise_P_0p03to50Hz_ODF.xml 2023-02-07_1828_H1SUSSRM_M3_WhiteNoise_Y_0p03to50Hz_ODF.xml (Blue ref trace is undamped, Black ref trace is old filters, Red live trace is Level 2 filters) We'll get more data and begin to process it in the coming weeks.