Calibrated DARM during RH steps

Jennie, Elenna, Craig

For seven calibration meeasurements over the last two weeks I captured the thermal state of the interferometer, and used the broadband calibration injection taken at that time, and a 10 minute DARM measurement from a nearby quiet time, to get the calibration corrected DARM plots.

The thermal states were captured using thermal_state_capture.py in labutils.

The data was processed using Run_DARM_calib.ipynb in ligo/jennifer.wright/Documents/thermal_state

The BB injection measurements I used are in: /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O3/H1/Measurements/FullIFOSensingTFs

The DARM spectra I used for quiet times are in /ligo/home/jennifer.wright/Documents/thermal_state
 

Calibrated DARM plots are saved in /ligo/gitcommon/labutils/pcal_bb_inj_quick_cal/plots and data is saved in /ligo/gitcommon/labutils/pcal_bb_inj_quick_cal/data 


 

BB Cal Injection Start DARM measurement start Input Power of IFO to nearest W Guardian State During Quiet time DARM measurement filename BB Cal Injection filename Thermal State Filename
1364697812 1364699612 60 600 2023-04-05_0313UTC_H1_DARMSPEC_0-1Hz.xml 2023-04-04_1945UTC_H1_PCALY2DARMTF_BB_3min.xml therm_state_1364697812.txt
1364775641 1364777441 60 700 2023-04-06_0050UTC_H1_DARMSPEC_0-1Hz.xml 2023-04-05_1727UTC_H1_PCALY2DARMTF_BB_3min.xml therm_state_1364775641.txt
 
1364872253 1364871648 60 700 2023-04-07_0300UTC_H1_DARMSPEC_0-1Hz.xml 2023-04-07_0316UTC_H1_PCALY2DARMTF_BB_3min.xml therm_state_1364872253.txt
 
1364882935 1364885358 70 700 2023-04-07_0649UTC_H1_DARMSPEC_0-1Hz.xml 2023-04-07_0612UTC_H1_PCALY2DARMTF_BB_3min.xml therm_state_1364882935.txt
 
1365031551 1365030706 70 700 2023-04-08_2311UTC_H1_DARMSPEC_0-1Hz.xml 2023-04-08_2327UTC_H1_PCALY2DARMTF_BB_3min.xml therm_state_1365031551.txt
 
1365040525 1365039740 70 600 2023-04-09_0142UTC_H1_DARMSPEC_0-1Hz.xml 2023-04-09_0412UTC_H1_PCALY2DARMTF_BB_3min.xml therm_state_1365040525.txt
 
1365385287 1365383774 78 700 2023-04-13_0115UTC_H1_DARMSPEC_0-1Hz.xml 2023-04-12_0145UTC_H1_PCALY2DARMTF_BB_3min.xml therm_state_1365385287.txt
 

 

I am going to add post some more DARM measurements from other days as I process them.

Non-image files attached to this report
Comments related to this report
jennifer.wright@LIGO.ORG - 18:44, Thursday 20 April 2023 (68857)

I plotted all the DARM spectra scaled by the PCAL BB measurement on the same graph, and corrected the parts where the coherence was low to match the unscaled DARM measurement.

Plot is in /ligo/home/jennifer.wright/Documents/thermal_state/pcal_corrected_darm_2023-04-05_0313UTC-to-2023-04-13_0115UTC.pdf

And code is in /ligo/home/jennifer.wright/Documents/thermal_state/Run_DARM_calib.ipynb.

Non-image files attached to this comment
jennifer.wright@LIGO.ORG - 18:16, Monday 24 April 2023 (68964)TCS

I updated the code to include GPS reference times for the DARM spectra and some additional measurements which were taken on the 10th, 14th and 20th of April. 

Code is in: /ligo/home/jennifer.wright/Documents/thermal_state/Run_DARM_calib_20230424.ipynb

Data for broadband calibration TFs to DARM is taken from:

/ligo/groups/cal/data/H1/measurements/PCALY2DARM_BB/

/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O3/H1/Measurements/FullIFOSensingTFs/

Data for quiet times:

/ligo/home/jennifer.wright/Documents/thermal_state/*H1_DARMSPEC_0-1Hz.xml

Non-image files attached to this comment