MC Baffle by HAM2 successfully angled to ten degrees

Robert, Mitchell, Corey, Tony, TJ, Alena, Eddie, Betsy, the SLiC team.

The baffle by HAM2  can, at 5 degrees, specularly reflect some scattered light back to beam spots and has been shown to produce scattering noise (https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=74772). Today we changed the angle of the baffle to 10 degrees using new hardware designed at CIT. The new hardware and the procedure worked well. The figure shows photos of the work.

Non-image files attached to this report
Comments related to this report
betsy.weaver@LIGO.ORG - 20:21, Wednesday 31 January 2024 (75660)

Here's TJ in HAM3 locking the ISI via only 1 open door and squeezing through around either side of the table.

Also a door crew snapshot.

Images attached to this comment
corey.gray@LIGO.ORG - 09:16, Thursday 01 February 2024 (75665)EPO

Tagging EPO for Stray Light Baffle & Door Removal photos.