Reports until 17:23, Wednesday 13 March 2024
H1 ISC
jennifer.wright@LIGO.ORG - posted 17:23, Wednesday 13 March 2024 - last comment - 10:59, Thursday 14 March 2024(76358)
9 and 45 MHz modulation depth up/down test ran in thermalised IFO

Craig, Jennie W.

In order to calibrate POPAIR_RF9 and RF18 PDs in terms of PRG9 and 45, we ran Craig's labutils/mod_depth_up_down_test.

We realised our mod depth up/down test from the other day was changing the gain of the POPAIR diodes to compensate the drop in optical gain as the modulation depths are changed.

We don't want this as it negates the change on the diodes we are trying to measure for our calibration.

Craig commented out these lines in the step_9 and step_45 functions.

 

We also were overestimating the PRG as the beam on IM4_TRANS PD was not well-centred.

In this log we stepped the alignment in lock to optimise on the IM4 TRANS QPD and the ISS array.

The mod-up-down-test was taken during low frequency measurements of new DARM.

Times RF9 was stepped down are 1394406378 GPS, then back up at 1394406438 GPS.

Times RF45 wa stepped down are 1394406448 GPS, then back up at 1394406508 GPS.

After this test Craig did more optimisation of the input alignment with IM 1 and 3.

Then I waited a bit and took another test. Both were done with a well thermalised IFO of more 10 hours lock.

Times RF9 was stepped down are 1394409674 GPS, then back up at 1394409735 GPS.

Times RF45 wa stepped down are 1394409744 GPS, then back up at  1394409804GPS.

 

First image is beam diverter that needs unshuttered for this test.

Second image shows the plots from the first test, third image shows the second test.

Images attached to this report
Non-image files attached to this report
Comments related to this report
craig.cahillane@LIGO.ORG - 10:59, Thursday 14 March 2024 (76379)
Results from the second scan, taken starting at 1394409654 and going to 1394409887:

Channels9 MHz45 MHzCarrier
H1:IMC-PWR_IN_OUT160.0130.0150.972
H1:IMC-IM4_TRANS_NSUM_OUT160.0130.0150.972
H1:LSC-REFL_A_LF_OUT160.0400.0480.912
H1:LSC-REFL_B_LF_OUT160.0350.0420.924
H1:LSC-POP_A_LF_OUT160.0170.0080.975
H1:ASC-POP_A_NSUM_OUT160.0170.0090.975
H1:ASC-POP_B_NSUM_OUT160.0170.0080.975
H1:ASC-AS_C_NSUM_OUT160.1760.4930.331
H1:ASC-OMC_A_NSUM_OUT160.1770.6090.213
H1:ASC-OMC_B_NSUM_OUT160.1790.5390.282
H1:ASC-X_TR_A_NSUM_OUT160.0040.0060.990
H1:ASC-X_TR_B_NSUM_OUT160.0040.0060.990
H1:ASC-Y_TR_A_NSUM_OUT160.0040.0070.989
H1:ASC-Y_TR_B_NSUM_OUT160.0040.0070.989
Power-recycling gains for sidebands and carrier 9 MHz PRG = 64.7 45 MHz PRG = 27.8 Carrier PRG = 49.6 Reflection ratios for sidebands and carrier 9 MHz reflection ratio = 0.198 45 MHz reflection ratio = 0.205 Carrier reflection ratio = 0.060