Reports until 18:38, Saturday 11 May 2024
H1 SEI
oli.patane@LIGO.ORG - posted 18:38, Saturday 11 May 2024 (77785)
H1 ISI CPS Noise Spectra Check FAMIS

Closes FAMIS#25990, last checked 77540

Things of note:
- ITMY ST1 V2 - slightly elevated compared to previous measurements
- BS ST2 H1, H2, and H3 - significant hump between 5 and 11 Hz
- ETMX ST1 V1 - slightly elevated
- ETMX ST2 H1, H2, and H3 - significant hump between 6 and 15 Hz
- ETMY ST2 H1, H2, and H3 - significant hump between 6 and 9.5 Hz

Non-image files attached to this report