Displaying report 1-1 of 1.
Reports until 14:25, Thursday 06 June 2024
H1 ISC
jennifer.wright@LIGO.ORG - posted 14:25, Thursday 06 June 2024 - last comment - 15:30, Friday 28 June 2024(78282)
Measured OMC Scan before Moving spot in OFI Today

At the start of commissioning today, before we got to NLN and were having trouble locking the OMC, I took an OMC mode scan when we were locked at 10W.

We manually move the OMC_PZT2_OFFSET to its lowest slider value then run the template which does two 100s ramps of this PZT.

Posting for posterity.

Time of Scan = 15:23:43 UTC

200s length. See template in /ligo/home/jennifer.wright/Documents/OMC_scan/2024_06_06_OMC_Scan_15-23UTC.xml

Images attached to this report
Comments related to this report
jennifer.wright@LIGO.ORG - 15:30, Friday 28 June 2024 (78730)

Analysed mode scan and C02 mode for this full-lock scan but since we have mainly been doing single bounce to look at losses and all the sidebands were on, just posting it here for posterity. The mode-matching calculation has to take into account all the sidebands I think.

Analysis code is In OMCscan_nosidebands13.py and fit_two_peaks_no_sidebands13.py in /gitcommon/labutils/omc_scan/figures/2024-06-06 on the /dev branch (ie. it will not be on the workstation branch as this is the master branch).

Non-image files attached to this comment
Displaying report 1-1 of 1.