DARM Offset Test:
Test was run without issues and upon checking the PCAL X and Y Excitation screens, the only differences I can see before vs. after are in the OSC_TRAMP Times:
PCALX: OSC TRAMP (sec) OSC1 was 3 and went to 5
PCALY: OSC TRAMP (sec) OSC1-9 were 10 and went to 5.
I reverted these to their before values - everything else is the same (screenshots below).
I accidentally placed the analysis for this test as a comment on the wrong alog. Thanks Vicky for pointing this out!
See here for the optical gain and DARM offset plots.
I added a plot showing the loss ( inverse of the slope of attached graph) between the input of HAM 6 (AS port) and the DCPDs as in this entry.
This loss term is 1/1.247 = 0.802 with 653.7 mW of light insensitive to DARM at the AS port.