Reports until 10:35, Thursday 01 August 2024
H1 SUS (SUS)
rahul.kumar@LIGO.ORG - posted 10:35, Thursday 01 August 2024 - last comment - 12:33, Thursday 01 August 2024(79409)
HAM6 door close-out transfer function measurements on suspensions looks healthy

This morning I took transfer function measurements on all of the suspensions in HAM6 chamber and they look healthy.

The templates are given below,

/ligo/svncommon/SusSVN/sus/trunk/OMCS/H1/OMC/SAGM1/Data

2024-08-01_1900_H1SUSOMC_M1_WhiteNoise_L_0p02to50Hz.xml
2024-08-01_1900_H1SUSOMC_M1_WhiteNoise_P_0p02to50Hz.xml
2024-08-01_1900_H1SUSOMC_M1_WhiteNoise_R_0p02to50Hz.xml
2024-08-01_1900_H1SUSOMC_M1_WhiteNoise_T_0p02to50Hz.xml
2024-08-01_1900_H1SUSOMC_M1_WhiteNoise_V_0p02to50Hz.xml
2024-08-01_1900_H1SUSOMC_M1_WhiteNoise_Y_0p02to50Hz.xml

 

/ligo/svncommon/SusSVN/sus/trunk/HTTS/H1/OM1/SAGM1/Data

2024-08-01_1900_H1SUSOM1_M1_WhiteNoise_L_0p02to50Hz.xml
2024-08-01_1900_H1SUSOM1_M1_WhiteNoise_P_0p02to50Hz.xml
2024-08-01_1900_H1SUSOM1_M1_WhiteNoise_Y_0p02to50Hz.xml

 

/ligo/svncommon/SusSVN/sus/trunk/HXDS/H1/OM2/SAGM1/Data

2024-08-01_1600_H1SUSOM2_M1_WhiteNoise_L_0p02to50Hz.xml
2024-08-01_1600_H1SUSOM2_M1_WhiteNoise_P_0p02to50Hz.xml
2024-08-01_1600_H1SUSOM2_M1_WhiteNoise_Y_0p02to50Hz.xml

 

/ligo/svncommon/SusSVN/sus/trunk/HTTS/H1/OM3/SAGM1/Data

2024-08-01_1630_H1SUSOM3_M1_WhiteNoise_L_0p02to50Hz.xml
2024-08-01_1630_H1SUSOM3_M1_WhiteNoise_P_0p02to50Hz.xml
2024-08-01_1630_H1SUSOM3_M1_WhiteNoise_Y_0p02to50Hz.xml

 

The postprocessing of the data is still ongoing and the plots will be posted soon.

Comments related to this report
ryan.crouch@LIGO.ORG - 11:39, Thursday 01 August 2024 (79411)SUS

I commited all the data to the svn and processed the results.

OM1:

Looks good.

OM2:
All the plots look frequency shifted a Hz smaller except for in L.

OM3:

Looks good.

OMC:

Some peaks shifted to the right/larger frequency by <1Hz or so.

 

Non-image files attached to this comment
rahul.kumar@LIGO.ORG - 11:50, Thursday 01 August 2024 (79412)

The current measurements taken on OM2 is consistent with previous results (see LHO alog 65028) and so its all good.

rahul.kumar@LIGO.ORG - 12:33, Thursday 01 August 2024 (79414)SUS

OMC is also healthy and consistent with previous measurements taken in the past 1 year - see plot attached below.

Non-image files attached to this comment