At 15:34:40 Wed 09oct2024 PDT a corner station dolphin glitch caused DACKILLs for h1sush34, h1lsc0 and h1omc0.
h1sush7 has other Dolphin logs associated with previous glitches. https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=75921 [Wed Feb 21 11:33:40 2024] IXH Adapter 0 : Port 0 is not operational -- UpTime: 0 sec - Event = 0 https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=79561 [Thu Aug 15 16:37:15 2024] IXH Adapter 0 : Port 0 is not operational -- UpTime: 0 sec - Event = 0 And today: [Wed Oct 9 15:34:25 2024] IXH Adapter 0 : Port 0 is not operational -- UpTime: 0 sec - Event = 0 [Wed Oct 9 15:34:25 2024] dis-ix-ntb: dis-ix-ntb0: Detected IXS600 (601) switch, SUB2, port 1, global port 12 [Wed Oct 9 15:34:25 2024] IXH Adapter 0 : Local adapter is connected to IXS600 switch, SUB2, port 1 [Wed Oct 9 15:34:25 2024] IXH Adapter 0 : Link 0 is operational - Link width: x8 - PCIe Gen 2 -- Downtime: 0 sec We might want to check cable when we get a chance, and if that dose not resolve the issue consider replacing the card.